Patient Monitor Multi Parameter Monitoring of parameters of ECG, RESP, NIBP, SpO2, PR and TEMP.
Applications 
This multi-parameter monitor can be used for monitoring of parameters of ECG, RESP, NIBP, SpO2 and TEMP. Other optional monitoring applications are also available, such as mainstream, sidestream EtCO2 and 1 or 2-Channel IBP.
Call for Order:(+88) 01713-99 24 72  (+88) 01913 -50 24 40 

৳ 60,000.00 ৳ 75,000.00

Product Description:

Patient Monitor

In order to cater to the numerous necessities of the patrons, we have been able to provide a wide range of Multiparameter Monitor.

Features:

  • Excellent visibility
  • Flawless finish
  • Easy maintenance

Other Details:

  • Compact and flexible enough to adapt to your particular needs
  • Configurable to suit your requirements
  • Well-suited for use in Surgical, and critical care environments
  • VSM 5 patient monitor an affordable solution for your department
  • Standard parameters: ECG, RESP, NIBP, SPO2, PR/HR
  • 8″ High resolution color TFT LCD display
  • Real time S-T segment analysis, pace-maker detection
  • Multi-Lead ECG waveforms display in phase
  • Large volume of tabular and graphic trends information storage and easy to recall
  • Efficient resistance to interference of defibrillator and HF knife
  • Typically Up to 5 hours working time.
  • Specifications of  Multi-Parameter Monitor
    ECG Heart rate display range 15bpm ~ 350bpm
    Heart rate display accuracy ± 1% or ± 2bpm, whichever is greater
    Sweeping speed 12.5mm /s, 25mm/s, 50mm/s
    Sensitivity selection ×1/2, 5mm/mV ×1, 10mm/mV ×2, 20mm/mV
    CMRR ≥ 89dB
    RESP Measuring range 0rpm~120rpm
    Accuracy ±5% or ±2 rpm
    Alarm limits setting range 0rpm~120rpm
    TEMP Measuring range 25.0℃ ~45.0℃
    Measuring accuracy ±0.2 ℃
    Responding time ≤150s
    NIBP Measuring method Oscillometric Technique
    Measuring range 0 mmHg~300mmHg
    Accuracy Maximal mean difference ±5 mmHg
    Maximal standard deviation 8 mmHg
    Measurement range Adult SYS 40 ~ 255 mmHg
    MAP 20 ~ 215 mmHg
    DIA 10 ~ 195 mmHg
    Pediatric patient SYS 40 ~ 200 mmHg
    MAP 20 ~ 165 mmHg
    DIA 10 ~ 150 mmHg
    Neonate SYS 40 ~ 135 mmHg
    MAP 20 ~ 110 mmHg
    DIA 10 ~ 95 mmHg
    SpO2 Measuring range 35%~100%
    Low perfusion capability 0.4%~5%
    Accuracy Not greater than 3% for SpOrange from 70% to 100%
    PR Measuring range 30bpm~240bpm
    Measuring accuracy ±2bpm or ±2%, whichever is greater